Comparison of Left Ventricular Global Longitudinal Strain Measured with Real Time Triplane and 2-Dimensional Echocardiography in Patients with Atrial Fibrillation

Authors

  • Ling Yun Kong Peking University People’s Hospital.
  • Chao Yu Peking University People’s Hospital
  • Jihong Guo Peking University People’s Hospital
  • Tiangang Zhu Peking University People’s Hospital

DOI:

https://doi.org/10.17987/icfj.v4i0.156

Keywords:

Atrial Fibrillation, Left Ventricle, Triplane Echocardiography, Speckle Tracking, Strain

Abstract

Background: Left ventricular (LV) global longitudinal peak systolic strain (GLPS, also known as GLS) based on speckle tracking echocardiography (STE) is validated to evaluate global LV systolic function, particularly the global average GLPS (GLPSAvg, which is averaged from three apical longitudinal views). But its application is limited in patients with atrial fibrillation (AF) due to its variability of cycle lengths. A novel imaging technique, real time triplane echocardiography (3PE), allows simultaneous presentation of apical 4-, 2-, and 3- chamber views within one ultrasonic view. We compared GLPS measures using 3PE and conventional 2-dimensional echocardiography (2DE) in patients with AF.

Methods: Patients with AF and a control group with sinus rhythm were enrolled prospectively. Three apical sectional GLPSs and GLPSAvg were measured with conventional 2D (2D-STE) and 3PE (3P-STE) modes. Comparison, correlation and agreement of measurements with both modes were made. Ten patients were selected randomly for reproducibility study.

Results: (1) A total of 39 patients with AF and 38 control subjects were analyzed. Adequate apical 3PE views were acquired in most subjects (95%). Measurement of GLPSs with 3P-STE was more readily available than with 2D-STE in AF group (97.5% vs. 60.0%, P=000). (2) The GLPSs measured with 3P-STE was constantly lower than that of 2D-STE, but linearly correlated, with GLPSAvg revealing the best correlation (r=0.86, P=0.00 in both groups). (3) The reproducibility of GLPS measured by 3P-STE was valid.

Conclusions: Triplane echocardiography may extend the use of LV GLPSAvg to patients with AF for assessment of LV systolic function.

Author Biography

Ling Yun Kong, Peking University People’s Hospital.

Resident physician, Department of Cardiology

References

Boriani G, Diemberger I. Globalization of the epidemiologic, clinical, and financial burden of atrial fibrillation. Chest. 2012;142(6):1368-1370. doi: 10.1378/chest.12-1091.

Ling LH, Khammy O, Byrne M, et al. Irregular rhythm adversely influences calcium handling in ventricular myocardium: implications for the interaction between heart failure and atrial fibrillation. Circ Heart Fail. 2012;5(6):786-793. doi: 10.1161/CIRCHEARTFAILURE.112.968321.

Lee CS, Lin TH, Hsu PC, et al. Measuring left ventricular peak longitudinal systolic strain from a single beat in atrial fibrillation: validation of the index beat method. J Am Soc Echocardiogr. 2012;25(9):945-952. doi: 10.1016/j.echo.2012.06.006.

Feigenbaum H, Mastouri R, Sawada S. A practical approach to using strain echocardiography to evaluate the left ventricle. Circ J. 2012;76(7):1550-1555. doi:http://doi.org/10.1253/circj.CJ-12-0665

Saito M, Negishi K, Eskandari M, et al. Association of Left Ventricular Strain with 30-Day Mortality and Readmission in Patients with Heart Failure. J Am Soc Echocardiogr. 2015;28(6):652-666. doi: 10.1016/j.echo.2015.02.007.

Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015;28(1):1-39. doi: 10.1016/j.echo.2014.10.003.

Kusunose K, Yamada H, Nishio S, et al. Index-beat assessment of left ventricular systolic and diastolic function during atrial fibrillation using myocardial strain and strain rate. J Am Soc Echocardiogr. Sep;25(9). 2012;25(9):953-959. doi: 10.1016/j.echo.2012.06.009.

Zhang Y, Mazgalev TN. Achieving regular slow rhythm during atrial fibrillation without atrioventricular nodal ablation: selective vagal stimulation plus ventricular pacing. Heart Rhythm. 2004;1(4):469-475. doi: http://dx.doi.org/10.1016/j.hrthm.2004.06.011

Rodevand O, Bjornerheim R, Aakhus S, Kjekshus J. Left ventricular volumes assessed by different new three-dimensional echocardiographic methods and ordinary biplane technique. Int J Card Imaging. 1998;14(1):55-63. PMID: 9559379

Van de Veire NR, Yu C-M, Ajmone-Marsan N, et al. Triplane tissue Doppler imaging: a novel three-dimensional imaging modality that predicts reverse left ventricular remodelling after cardiac resynchronisation therapy. Heart. 2008;94(3):e9. doi:10.1136/hrt.2007.122564

Ren M, Tian J-W, Leng X-P, Wang H-M, Wang Y, Wang Z-Z. Assessment of Global and Regional Left Ventricular Function After Surgical Revascularization in Patients With Coronary Artery Disease by Real-time Triplane Echocardiography. J Ultrasound Med. 2009;28(9):1175-1184. PMID: 19710215

Clark DM, Plumb VJ, Epstein AE, Kay GN. Hemodynamic effects of an irregular sequence of ventricular cycle lengths during atrial fibrillation. J Am Coll Cardiol. 1997;30(4):1039-1045. doi:10.1016/S0735-1097(97)00254-4

Boettler P, Hartmann M, Watzl K, et al. Heart rate effects on strain and strain rate in healthy children. J Am Soc Echocardiogr. 2005;18(11):1121-1130. DOI: http://dx.doi.org/10.1016/j.echo.2005.08.014

Popović ZB, Yamada H, Mowrey KA, et al. Frank-Starling mechanism contributes modestly to ventricular performance during atrial fibrillation. Heart Rhythm. 2004 1(4):482-489. DOI: http:// dx.doi.org/10.1016/j.hrthm.2004.06.016

López-Candales A. Automated functional imaging for assessment of left ventricular mechanics in the presence of left ventricular hypertrophy. Echocardiography. 2014;31(5):605-614. doi: 10.1111/echo.12441.

Lee M, Chang SA, Cho EJ, et al. Role of strain values using automated function imaging on transthoracic echocardiography for the assessment of acute chest pain in emergency department. Int J Cardiovasc Imaging. 2015 31(3):547-556. doi: 10.1007/s10554-015-0588-z.

Eroglu E, D'hooge J, Herbots L, et al. Comparison of real-time tri-plane and conventional 2D dobutamine stress echocardiography for the assessment of coronary artery disease. Eur Heart J. 2006;27(14):1719-1724. DOI: http://dx.doi.org/10.1093/eurheartj/ehl023 1719-1724 First published online: 23 May 2006

Amundsen BH, Helle-Valle T, Edvardsen T, et al. Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging. J Am Coll Cardiol. 2006 47(4):789-793. doi:10.1016/j.jacc.2005.10.040

Negishi K, Negishi T, Agler DA, Plana JC, Marwick TH. Role of temporal resolution in selection of the appropriate strain technique for evaluation of subclinical myocardial dysfunction. Echocardiography. 2012;29(3):334-339. doi: 10.1111/j.1540-8175.2011.01586.x.

Lang RM, Bierig M, Devereux RB, et al. Recommendations for Chamber Quantification: A Report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, Developed in Conjunction with the European Association of Echocardiography, a Branch of the European Society of Cardiology. J Am Soc Echocardiogr. 2005;18(12):1440-1463. DOI: http://dx.doi.org/10.1016/j.echo.2005.10.005

Shewan LG, Coats AJS, Henein M. Requirements for ethical publishing in biomedical journals. International Cardiovascular Forum Journal 2015;2(2). doi: 10.17987/icfj.v2i1.4.

Downloads

Published

2015-12-04

Issue

Section

Original Article